GUIDE TO INSTALLATION AND OPERATION
SDA-1401 | 9
3.4.4
The Reclocker tab
Use the pulldown in this panel to set the SDA-1401’s reclocker
operating mode for DVB-ASI signals at 270 Mbps:
Bypass – the input clock timing is passed through to the
output
On – the data stream is reclocked as it passes through the
SDA-1401
Reclocking is automatically bypassed for SMPTE 310M/DVI-SSI
signals.
The card automatically provides equalization for up to 350 m of
Belden 1694A cable at 270 Mbps.
3.4.5
The Alarms tab
This panel allows the alarm reporting of the SDA-1401 to be
configured. The panel opens in a new window when the button is
clicked, and can be resized if needed.
The panel is organized in columns.
Status/Name
This contains an expandable tree listing all the alarms reported by
this SDA-1401 card.
Each alarm name includes an icon that shows its current
status
The Overall alarm and GSM contribution columns contain
pulldown lists that allow the level of contribution of each individual
alarm to the alarm named in the column heading to be set.
Click on the icon to see the pulldown showing the available
levels
Overall Alarm
This column allows configuration of the contribution of each
individual alarm to the Overall Alarm associated with this card.
The Overall Alarm is shown in the upper left corner of the
iControl panel, and also appears at the bottom of the
Status/Name column.
Figure 3.5 Reclocker tab
Figure 3.6 Alarms tab